4.11 Emergency vehicles

To enable the access and operation of a fire appliance, a clear width of 3.7m is required that allows a pump appliance to get within 45m of all points in a home [Reference 11]. An access route can be reduced to an absolute minimum 2.75 m for short distances points, such as at modal filters and traffic calming features, provided that the vehicle can still meet the 45m requirement.

The local fire authority must be consulted where carriageway widths are to be reduced below 3.7m.

In all cases, consideration should be given to parking restrictions to ensure clear access to fire vehicles.

Blocks of flats over 4 storeys have additional access requirements, further information is provided within Building Regulations Approved Document B and the local Building Control Authority.